The violet, 1,000' 1801B Multi-Conductor Single-Pair Bulk Cable from Belden features 24 AWG stranded (7 x 32) tinned copper conductors, plenum, foam FEP Teflon insulation, twisted pairs, an overall Beldfoil shield (100% coverage), a 24 AWG drain wire, and a Flamarrest jacket.
In the Box
Belden 1801B Multi-Conductor Single-Pair Bulk Cable (1,000', Violet)
Conductor | Number of Pairs: 1, 24 AWG Stranding: 7 x 32 Conductor Material: TC (Tinned Copper) Diameter: 0.024" (0.610 cm) |
Insulation Material | Insulation Trade Name: Teflon Insulation Material: FFEP (Foam Fluorinated Ethylene Propylene) Diameter: 0.066" (0.167 cm) |
Outer Shield Material | Outer Shield Trade Name: Beldfoil Type: Tape Outer Shield Material: Aluminum foil-polyester tape Coverage (%): 100 |
Drain Wire | 24 AWG Stranding: 7 x 32 Drain Wire Conductor Material: TC (Tinned Copper) |
Outer Jacket Material | Outer Jacket Trade Name: Flamarrest Outer Jacket Material: LS PVC (Low Smoke Polyvinyl Chloride) |
Cable | Cabling Color Code: 1: Black and red Nominal Diameter: 0.165" (0.419 cm) Teflon is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc. |
Impedance | 110 ? |
Inductance | 0.18 �H/feet |
Capacitance | Nominal Capacitance Conductor to Conductor: 12 pF/feet Nominal Capacitance Conductor to Other Conductor & Shield: 26 pF/feet |
Velocity of Propagation | 78% |
Conductor DC Resistance | 23.7 at 20�C (?/1,000') |
Maximum Voltage | 300 Vrms (UL) |
Current | 2.75 A per conductor at 25�C |
Plenum | Non-Plenum Number: 1800B Plenum: Yes |
Attenuation | Frequency (MHz): 0.384, Attenuation (dB/100'): 0.82 Frequency (MHz): 0.705, Attenuation (dB/100'): 1.01 Frequency (MHz): 0.768, Attenuation (dB/100'): 1.02 Frequency (MHz): 1.024, Attenuation (dB/100'): 1.08 Frequency (MHz): 1.411, Attenuation (dB/100'): 1.15 Frequency (MHz): 1.536, Attenuation (dB/100'): 1.16 Frequency (MHz): 2.048, Attenuation (dB/100'): 1.23 Frequency (MHz): 2.822, Attenuation (dB/100'): 1.34 Frequency (MHz): 3.072, Attenuation (dB/100'): 1.38 Frequency (MHz): 4.096, Attenuation (dB/100'): 1.58 Frequency (MHz): 5.645, Attenuation (dB/100'): 1.79 Frequency (MHz): 6.144, Attenuation (dB/100'): 1.85 Frequency (MHz): 8.192, Attenuation (dB/100'): 2.05 Frequency (MHz): 11.290, Attenuation (dB/100'): 2.34 Frequency (MHz): 12.288, Attenuation (dB/100'): 2.43 Frequency (MHz): 24.576, Attenuation (dB/100'): 3.33 |
Compliance | NEC / (UL) Specification: CMP CEC/C (UL) Specification: CMP EU Directive 2011/65/EU (ROHS II) EU CE Mark EU Directive 2000/53/EC (ELV) EU Directive 2002/95/EC (RoHS) EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005 EU Directive 2002/96/EC (WEEE) EU Directive 2003/11/EC (BFR) CA Prop 65 (CJ for Wire and Cable) MII Order #39 (China RoHS) Other Specification: AES/EBU CSA Flame Test: FT6 |
Temperature | Operating Temperature Range: -4 to 167�F (-20 to +75�C) Non-UL Temperature Rating: 167�F (75�C) |
Tension Control | Recommended Pulling Tension: 16.50 lb (7.48 kg) |
Bend Radius | 1.75" (4.45 cm) |
Length | 1,000' (304.8 m) |
Weight | 12.00 lb (5.44 kg) |