APC BVK750M2 Overview
-
1Description
-
2Self-Test
-
3Quick Mute
-
4USB-A & USB-C Charging Ports
-
5LED Brightness Setting
-
6Auto-Restart Function
-
7Battery Backup & Surge Protector Outlets
-
8Voltage Sensitivity Adjustment
-
91Gb Network Protection
-
10Built-In AVR
- 11
Safely shut down computer systems and guard connected equipment from surges with the Back-UPS BVK750M2 Battery Backup & Surge Protector from APC. The UPS is armed with a total of four NEMA 5-15R outlets, all of which provide surge protection and backup power. In the event of a power outage, the UPS comes equipped with an internal battery that delivers up to 410W of power. The battery-powered outlets provide up to 1.97 minutes of use at full load and up to 9.7 minutes at half load. For electrical spikes, the UPS has a 350J surge energy rating. Other notable connections include 1Gb Ethernet ports for safeguarding network signals. There is also a USB-A and a USB-C port with a total of 10W of power available for device charging. Included along with the backup UPS is a USB-B to USB-A cable, a power cable, and a downloadable PowerChute software program to monitor energy usage and prevent data corruption by automatically saving files and shutting down a computer system.
Automatic test of the internal battery when UPS is turned on or when it operates in On Line Mode for 14 days.
Temporarily mute audible alarms such as On Battery with a short press of the Power button. A short double beep will confirm that Quick Mute has been activated.
USB-A & USB-C Charging Ports
Conveniently charge your mobile devices via one USB-A charging port and one USB-C charging port.
Control the LED brightness with a short press of the Power button during On Line mode.
Enables the UPS to restart automatically when main recovers after a complete battery discharge.
Battery Backup & Surge Protector Outlets
Keep your valuable devices running when the power is outside expected levels.
Voltage Sensitivity Adjustment
Easily adjust UPS voltage sensitivity (low, medium) in just a few easy steps.
Safeguards your equipment and valuable files from "back door" surges traveling along data lines without sacrificing network speed.
Instantly corrects low/high voltage fluctuations and is Active Power Correction.
Easy to use auto-shutdown software with power and energy management features.
In the Box
- APC Back-UPS BVK750M2 Battery Backup & Surge Protector
- USB-B to USB-A Cable (3.9' / 1.2m)
- Power Cord (4.9' / 1.5m)
Table of Contents
- Description
- Self-Test
- Quick Mute
- USB-A & USB-C Charging Ports
- LED Brightness Setting
- Auto-Restart Function
- Battery Backup & Surge Protector Outlets
- Voltage Sensitivity Adjustment
- 1Gb Network Protection
- Built-In AVR
-
APC BVK750M2 Specs
General
Total Outlets |
4 x NEMA 5-15R |
Protected Outlets |
4 x NEMA 5-15R (Battery and Surge) |
Plug Type |
NEMA 5-15P |
Data Line Protection |
RJ45 |
Communications |
USB via Type-B |
Emergency Power Off (EPO) Support |
Yes |
Transfer Time |
6 to 10 ms |
Power
Surge Energy Rating |
350 Joules |
Nominal Input Voltage |
120 VAC |
Input Voltage Range |
89 to 145 VAC |
Input Frequency |
50/60 Hz (Auto Sensing) |
Nominal Output Voltage |
120 VAC |
Output Frequency |
50/60 Hz ± 0.5 Hz |
Load Capacity |
750 VA |
Circuit Breaker Rating |
10 A |
Power Factor Correction |
0.55 |
Waveform |
Sine Wave |
Battery
Battery Capacity |
92 VAh |
Chemistry |
Lead-Acid |
Full-Load Runtime |
1.97 Minutes |
Half-Load Runtime |
9.7 Minutes |
Recharge Time |
6 Hours |
User Replaceable |
No |
Replacement Battery |
APCRBC178 |
External Battery Connection |
1 x IEC Jumper |
Environmental
Operating Temperature |
32 to 104°F / 0 to 40°C |
Operating Altitude |
0.0 to 9842' / 0 to 3000 m |
Certifications |
REACH, RoHS, WEEE *as per Manufacturer |
Physical
Cable Length |
4.9' / 1.5 m |
Rackmount Size |
None |
Dimensions (W x H x D) |
4.7 x 6.3 x 14" / 12 x 16 x 35.5 cm |
Weight |
12.1 lb / 5.5 kg |
Packaging Info
Package Weight |
14.695 lb |
Box Dimensions (LxWxH) |
17 x 10 x 7.7" |
APC BVK750M2 Reviews