- Cloud Compliant
- Local & Remote Access
- DDNS Service
- Individual Device Controls
- Monitored Variables
- Data Logging
- Ability to Export Logs
- Alert Events / Auto Ping
- Energy Management
- Scheduling
The RLNK-MON115-NS RackLink 15 A Inline Power Monitor from Middle Atlantic is a practical web-enabled power management system that sets a new standard for A/V installations. Set it up in less than 5 minutes and it will monitor the power and temperature conditions of your system, log and alert you to any irregularities, and even reboot or take another action to correct problems on its own. It is easy to set up and operate, with an open architecture that integrates seamlessly with leading control systems-even your smart phone-and is compatible with 'cloud'-based services but is not dependent on them.
- Easy set up, with simple plug & play installation
- Monitor and log numerous key environmental variables, including input voltage, load current, and local temperature
- Tracks and provides instantaneous notification of anomalous voltage, load current and temperature conditions
- Detailed logging of environmental variables and alerts
- Auto Ping monitors remote IP devices and automatically restarts if remote device stops responding
- Proactive and automatic fault resolution
- Local control of outlets via manual switches
- Integrated web server with either static or dynamic IP address for browser-based access and control
- Open-architecture serial communications protocol provides 100% cloud compliance, without cloud-dependence; and seamless integration into any RS-232 or TCP/IP-based architecture
- Extend control outside the rack to anywhere in the facility through dry contact outputs
- Data log for every monitored variable once every 5 minutes, and also immediately on every alert condition (surge status, threshold breaches, auto-ping no response, input voltage and connected load fluctuations)
- Data logs can be saved locally in CSV format, or extracted remotely via IP or RS-232
- Control systems can schedule specific commands to be sent to this device at set times
UPC: 656747179105
In the Box
Middle Atlantic RLNK-MON115-NS RackLink 15 A Inline Power Monitor
Form Factor | In-line module |
Surge Protection | Basic |
Outlets | Total: 1 Controlled: 0 Un-switched:1 |
Dry Contact Switch | Total: 0 Controlled: 0 Surge status: n/a |
Web Server | Yes, Integrated |
Connection Type | 3' (91.44 cm) SignalSafe IEC (15 A) |
Line Voltage | Nominal: 120 VAC Minimum: 80 VAC Maximum: 140 VAC |
Maximum Current Rating | 15 A (Rated: 12 A) |
Alerts | Input Voltage Low: 105 to 110 VAC High: 123 to 128 VAC Load Current Minimum: 0 A Maximum: 15 A Temperature Minimum: 0�F (-17.77�C) Maximum: 140�F (60�C) |
Surge Suppression | Peak Impulse Current: 30,000 A, 1 time 19,500 A, 2 times within 5 minutes 7000 As, 10 times within 2 minutes Maximum peak impulse current pulse as defined between line and neutral Maximum multiple impulse current derated per spec Protection Mode: Line to neutral only; no ground contamination Response Time: Less than 1 nanosecond Surge Energy Dissipation: 160 J EMI / RF Suppression: > 20 dB calculated line to neutral, 100 kHz to 1 Mhz (based on nominal impedance) |
Event Action | AutoPing no response/recovery: Email and/or control outlet and/or dry contact Over/under temperature: Email and/or control outlet and/or dry contact Over/under input voltage: Email Over/under load current: Email |
Communications | RS-232, TCP/IP, HTTP (integrated web server) |
Temperature | Operating: 32 to 140�F (0 to 60�C) Maximum thermistor operating and measurement range: 0 to 302�F (-17.77 to 150�C) |
Humidity Range | 0 to 95% RH, non-condensing thermistor |
Dimensions | 6 x 3 x 2.5" (152.4 x 76.2 x 63.5 mm) Unit can be mounted in any orientation. |
Packaging Info |
Package Weight | 3.085 lb |
Box Dimensions (LxWxH) | 13.0 x 5.5 x 5.0" |
All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.