{"product_id":"middle-atlantic-premium-iec-9-outlet-ce-rated-power-distribution-unit-16a","title":"Middle Atlantic Premium+ IEC 9-Outlet CE Rated Power Distribution Unit (16A)","description":"\u003cdiv\u003e\n \u003ch2\u003eMiddle Atlantic RLNK-P916R-IEC-NS Overview\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003cp\u003eThe \u003cb\u003ePremium+ IEC 9-Outlet CE Rated Power Distribution Unit\u003c\/b\u003e from \u003cb\u003e Middle Atlantic\u003c\/b\u003e provides monitoring, control, logging, security, and power protection capabilities for demanding AV applications. This device provides nine total CE rated IEC outlets with a maximum 16A rating, eight of which are controllable. Connect to your network via Ethernet for IP control, monitoring, and scheduling. Using the RackLink Remote Management System, you can monitor everything that is plugged into the PDU at all times.\u003c\/p\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       RackLink Cloud Enabled\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Designed specifically for AV professionals, RackLink Cloud provides an intuitive and centralized interface for device-level control. Seamlessly manage and monitor all your Premium+ PDUs and unlock new levels of efficiency, control, customer satisfaction, and revenue streams.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Network Security and IT Protocol Support\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       \u003cul\u003e\n        \u003cli\u003eSSL\/TLS Certificates\u003c\/li\u003e\n        \u003cli\u003eSSH\u003c\/li\u003e\n        \u003cli\u003eHTTPS\u003c\/li\u003e\n        \u003cli\u003eSelf-signed certificates\u003c\/li\u003e\n        \u003cli\u003e802.1X authentication\u003c\/li\u003e\n        \u003cli\u003eTACACS+, RADIUS, LDAP authentication\u003c\/li\u003e\n       \u003c\/ul\u003e\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Additional Details\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       \u003cul\u003e\n        \u003cli\u003eSupports 208V Single Phase for Broadcast and IT applications.\u003c\/li\u003e\n        \u003cli\u003eSave programming with integrated scheduling, variable timed sequencing, ping sequencing, auto healing, thresholds, and multiple notification options.\u003c\/li\u003e\n        \u003cli\u003eEasily connect to control systems and IT systems with universal compatibility through custom drivers, SNMP v3\/MIB, JSON-RPC, and 3rd party integrations.\u003c\/li\u003e\n        \u003cli\u003eConnect via Wi-Fi with a 3rd party dongle.\u003c\/li\u003e\n        \u003cli\u003eRemotely update firmware without having to shut down the PDU, ensuring system uptime.\u003c\/li\u003e\n        \u003cli\u003eSuperior metering accuracy of total power draw down to outlet level including current, voltage, power, power factor, and energy usage.\u003c\/li\u003e\n        \u003cli\u003eConnect multiple environmental sensors to monitor the temperature and humidity and alert potential threats that could cause system downtime\u003c\/li\u003e\n        \u003cli\u003eBuilt in partnership with Raritan, a leader in the intelligent power market, using their Xerus platform to deliver robust security features and intelligence.\u003c\/li\u003e\n        \u003cli\u003eCompliant with AVIXA Energy Management Standard to support energy efficient AV system design, monitoring and optimization.\u003c\/li\u003e\n       \u003c\/ul\u003e\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     UPC: 656747406058\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003ch4\u003eItems Included\u003c\/h4\u003e\n   \u003cul\u003e\n    \u003cli\u003e\u003cspan\u003eMiddle Atlantic Premium+ IEC 9-Outlet CE Rated Power Distribution Unit (16A)\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003eIEC C20 to IEC C19 Power Cord (9')\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003eLimited 3-Year Manufacturer Warranty\u003c\/span\u003e\u003c\/li\u003e\n   \u003c\/ul\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003ch4\u003eAdditional Resources \u003c\/h4\u003e\n \u003cp\u003eNo additional resources available\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003ch2\u003eMiddle Atlantic RLNK-P916R-IEC-NS Specs\u003c\/h2\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Key Specs\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eMetering\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eYes\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eBattery Backup\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eNo\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eOutlets\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e9x IEC-320 C13\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eAdditional I\/O\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e2x RJ45\u003cbr\u003e2x USB-A\u003cbr\u003e1x USB-B\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eSurge Protection\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eNo \u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eType\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eDistributor\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eAmp Rating\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e16 A\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eNumber of Circuits\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e\u003cspan\u003eNot Specified by Manufacturer\u003c\/span\u003e\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eMetering\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eYes\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eBattery Backup\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eNo\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eIntegrated Lamps\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eNo \u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Connections\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eOutlets\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e9x IEC-320 C13\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eWall Plug Type\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eIEC-320 C20\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eLamp I\/O\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eNo\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eAdditional I\/O\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e2x RJ45\u003cbr\u003e2x USB-A\u003cbr\u003e1x USB-B\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eWireless\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eNo\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Electrical\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eAC Input Power\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e100 to 240 VAC, 50 \/ 60 Hz \u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eDC Output Power\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e\u003cspan\u003eNot Specified by Manufacturer\u003c\/span\u003e\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eOutput Current\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e16 A\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eLoad Capacity\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e\u003cspan\u003eNot Specified by Manufacturer\u003c\/span\u003e\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eSequencing Delay\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Protection \u0026amp; Conditioning\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eCircuit Breaker\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eYes\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eMaximum Spike Current\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e16 A\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eSurge Protection\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eNo \u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Physical\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eCable Length\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e9' \/ 2.7 m \u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eCertifications\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eCE\u003cb\u003e\u003c\/b\u003e, CSA\u003cb\u003e\u003c\/b\u003e, UKCA\u003cb\u003e\u003c\/b\u003e, UL 62368-1\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eOperating Conditions\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e32 to 104?F \/ 0 to 40?C at 0 to 95% Humidity \u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eDimensions\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e19 x 9.8 x 1.8\" \/ 483 x 250 x 44.5 mm\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eWeight\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e7.9 lb \/ 3.6 kg\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e\u003cbr\u003eAll product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.","brand":"Middle Atlantic-10","offers":[{"title":"Default Title","offer_id":41977574424661,"sku":"MIRLNKP916IN:MIRLNKP916IN:bhpv","price":268005.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/1611\/files\/1749481187_1900035.jpg?v=1765969353","url":"https:\/\/www.tanotis.com\/products\/middle-atlantic-premium-iec-9-outlet-ce-rated-power-distribution-unit-16a","provider":"Tanotis","version":"1.0","type":"link"}