{"product_id":"lem-hob-50-p-sp33-current-sensor-voltage-output-1-45-accuracy-125-to-125-a-3-14-to-3-46-v","title":"LEM HOB 50-P\/SP33 Current Sensor, Voltage Output, 1.45 % Accuracy, -125 to 125 A, 3.14 to 3.46 V","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cdiv\u003e\n \u003cdiv\u003e\n  \u003cp\u003eHOB 50-P\/SP33 is a HOB-P\/SP33 series current transducer for the electronic measurement of current: DC, AC, pulsed with galvanic separation between the primary and the secondary circuit. With a market-leading response time of \u0026lt;lt\/\u0026gt; 200ns, compared to average response times of around 3microseconds, the HOB-P sensor is capable of measuring DC, AC or pulsed current up to 250A. At the same time, it is ideally suited to wide bandgap (WBG) power electronics use cases and applications that require enhanced immunity to the dv\/dt (acceleration) issues that SiC power modules are prone to. Among those applications stand handheld plasma cutters, welders, DC-DC converters, etc. Suitable for industrial application domain. Complies with IEC 61010-1: 2017, IEC 61010-2-30: 2017, IEC 61800-3: 2017, IEC 61800-5-1: 2007, IEC 62109-1: 2010 and UL 508: 2018 standards.\u003c\/p\u003e\n  \u003cul\u003e\n   \u003cli\u003ePrimary nominal RMS current of 50A\u003c\/li\u003e\n   \u003cli\u003eOpen loop multi-range current transducer with voltage output\u003c\/li\u003e\n   \u003cli\u003eHigh cut-off frequency up to 1MHz, enhanced immunity\u003c\/li\u003e\n   \u003cli\u003eIdeal for harsh environments with operating temperature range from -40°C to +105°C\u003c\/li\u003e\n   \u003cli\u003eCompact design for THT PCB mounting\u003c\/li\u003e\n   \u003cli\u003eLower noise and better dv\/dt behaviour vs other classical O\/L sensors from the market\u003c\/li\u003e\n   \u003cli\u003eLow power consumption, low offset temperature drift\u003c\/li\u003e\n   \u003cli\u003eSingle power supply +3.3V, creepage \/ clearance \u0026lt;gt\/\u0026gt; 11mm\u003c\/li\u003e\n   \u003cli\u003eGalvanic separation between primary and secondary circuit\u003c\/li\u003e\n   \u003cli\u003eFactory calibrated\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003ch3\u003eWarnings\u003c\/h3\u003e\n  \u003cp\u003eNever connect or disconnect the external power supply while the primary circuit is connected to live parts.\u003c\/p\u003e\n  \u003ch3\u003eNotes\u003c\/h3\u003e\n  \u003cp\u003eAlways wear protective clothing and gloves if hazardous live parts are present in the installation where the measurement is carried out.\u003c\/p\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e \u003ch4\u003eProduct details\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eSensor Output Type\u003c\/span\u003e\n     \u003cp\u003eVoltage\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eSupply Voltage DC Min\u003c\/span\u003e\n     \u003cp\u003e3.14V\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eSupply Voltage DC Max\u003c\/span\u003e\n     \u003cp\u003e3.46V\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eCurrent Measuring Range DC\u003c\/span\u003e\n     \u003cp\u003e-125A to 125A\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eCurrent Sensor Technology\u003c\/span\u003e\n     \u003cp\u003eOpen Loop, Hall Effect\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003ePrimary Current\u003c\/span\u003e\n     \u003cp\u003e50A\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eSecondary Signal Type\u003c\/span\u003e\n     \u003cp\u003e1.65V\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eOperating Temperature Min\u003c\/span\u003e\n     \u003cp\u003e-40°C\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eProduct Range\u003c\/span\u003e\n     \u003cp\u003eHOB-P Series\u003c\/p\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eSupply Voltage Range\u003c\/span\u003e\n     \u003cp\u003e3.14V to 3.46V\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eMeasured Current\u003c\/span\u003e\n     \u003cp\u003eAC \/ DC \/ Pulsed\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eAccuracy\u003c\/span\u003e\n     \u003cp\u003e± 1.45%\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eCurrent Measuring Range AC\u003c\/span\u003e\n     \u003cp\u003e-125A to 125A\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eResponse Time\u003c\/span\u003e\n     \u003cp\u003e100ns\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eAccuracy\u003c\/span\u003e\n     \u003cp\u003e1.45%\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eSensor Mounting\u003c\/span\u003e\n     \u003cp\u003eThrough Hole\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eOperating Temperature Max\u003c\/span\u003e\n     \u003cp\u003e105°C\u003c\/p\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cspan\u003eSVHC\u003c\/span\u003e\n     \u003cp\u003eNo SVHC (27-Jun-2024)\u003c\/p\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eOther details\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eLEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHOB 50-P\/SP33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003eEach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical Data Sheet EN\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.farnell.com\/datasheets\/3770927.pdf\" target=\"_blank\" title=\"View or Download\" download\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1034\/1611\/files\/file_4379f50c-e237-48f9-beae-a4e625c5b304_icon.png?9736775303194905289\" alt=\"Download technical document - datasheet - Tanotis India\" width=\"25\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003eAll product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.","brand":"LEM-10","offers":[{"title":"Default Title","offer_id":41635403825237,"sku":"4064799:1-VAT145:e14","price":2207.01,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/1611\/files\/66e81064a437ffa84861e416f9fa2860_7e8bd1db-59c7-4132-a1c9-b5d311130a3e.jpg?v=1755141432","url":"https:\/\/www.tanotis.com\/products\/lem-hob-50-p-sp33-current-sensor-voltage-output-1-45-accuracy-125-to-125-a-3-14-to-3-46-v","provider":"Tanotis","version":"1.0","type":"link"}