{"product_id":"lem-hob-100-p-current-sensor-voltage-output-1-25-accuracy-250-to-250-a-4-6-to-5-5-v","title":"LEM HOB 100-P Current Sensor, Voltage Output, 1.25 % Accuracy, -250 to 250 A, 4.6 to 5.5 V","description":"\u003cdiv\u003e\n HOB 100-P is a current transducer for the electronic measurement of current: DC, AC, pulsed with galvanic separation between the primary and the secondary circuit. With a market-leading response time of \u0026lt; 200ns, compared to average response times of around 3microseconds, the HOB-P sensor is capable of measuring DC, AC or pulsed current up to 250A. At the same time, it is ideally suited to wide bandgap (WBG) power electronics use cases and applications that require enhanced immunity to the dv\/dt (acceleration) issues that SiC power modules are prone to. Among those applications stand handheld plasma cutters, welders, DC-DC converters, etc. Suitable for industrial application domain. Complies with IEC 61010-1: 2017, IEC 61010-2-30: 2017, IEC 61800-3: 2017, IEC 61800-5-1: 2007, IEC 62109-1: 2010 and UL 508: 2018 standards.\n\u003c\/div\u003e \n\u003cdiv\u003e \n \u003cul\u003e \n  \u003cli\u003ePrimary nominal RMS current of 100A\u003c\/li\u003e \n  \u003cli\u003eOpen loop multi-range current transducer with voltage output\u003c\/li\u003e \n  \u003cli\u003eHigh cut-off frequency up to 1MHz, enhanced immunity\u003c\/li\u003e \n  \u003cli\u003eIdeal for harsh environments with operating temperature range from -40°C to +105°C\u003c\/li\u003e \n  \u003cli\u003eCompact design for THT PCB mounting\u003c\/li\u003e \n  \u003cli\u003eLower noise and better dv\/dt behaviour vs other classical O\/L sensors from the market\u003c\/li\u003e \n  \u003cli\u003eLow power consumption, level shifting, low offset temperature drift\u003c\/li\u003e \n  \u003cli\u003eSingle power supply +5V, creepage \/ clearance \u0026gt; 11mm, total error (ambient temp) \u0026lt; 1.45%\u003c\/li\u003e \n  \u003cli\u003eGalvanic separation between primary and secondary circuit\u003c\/li\u003e \n  \u003cli\u003eFactory calibrated\u003c\/li\u003e \n \u003c\/ul\u003e \n\u003c\/div\u003e \n\u003ch3\u003eFootnotes\u003c\/h3\u003e \n\u003cdiv\u003e\n Always wear protective clothing and gloves if hazardous live parts are present in the installation where the measurement is carried out.\n\u003c\/div\u003e \n\u003ch3\u003eWarnings\u003c\/h3\u003e \n\u003cdiv\u003e\n Never connect or disconnect the external power supply while the primary circuit is connected to live parts.\n\u003c\/div\u003e \u003ch4\u003eProduct details\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e \n\u003ctr\u003e\n\u003ctd\u003e Sensor Output:\n \n\n  Voltage \n\u003c\/td\u003e\n\u003c\/tr\u003e \n \n\u003ctr\u003e\n\u003ctd\u003e Supply Voltage DC Min:\n \n\n  4.6V \n\u003c\/td\u003e\n\u003c\/tr\u003e \n \n\u003ctr\u003e\n\u003ctd\u003e Supply Voltage DC Max:\n \n\n  5.5V \n\u003c\/td\u003e\n\u003c\/tr\u003e \n \n\u003ctr\u003e\n\u003ctd\u003e Current Measuring Range DC:\n \n\n  -250A to 250A \n\u003c\/td\u003e\n\u003c\/tr\u003e \n \n\u003ctr\u003e\n\u003ctd\u003e Current Measuring Range AC:\n \n\n  -250A to 250A \n\u003c\/td\u003e\n\u003c\/tr\u003e \n \n\u003ctr\u003e\n\u003ctd\u003e Response Time:\n \n\n  100ns \n\u003c\/td\u003e\n\u003c\/tr\u003e \n \n\u003ctr\u003e\n\u003ctd\u003e Accuracy %:\n \n\n  1.25% \n\u003c\/td\u003e\n\u003c\/tr\u003e \n \n\u003ctr\u003e\n\u003ctd\u003e Product Range:\n \n\n  HOB-P Series \n\u003c\/td\u003e\n\u003c\/tr\u003e \n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch4\u003eOther details\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eLEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHOB 100-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003eEach\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical Data Sheet EN\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.farnell.com\/datasheets\/3770926.pdf\" target=\"_blank\" title=\"View or Download\" download\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1034\/1611\/files\/file_4379f50c-e237-48f9-beae-a4e625c5b304_icon.png?9736775303194905289\" alt=\"Download technical document - datasheet - Tanotis India\" width=\"25\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cbr\u003eAll product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.","brand":"LEM-10","offers":[{"title":"Default Title","offer_id":40770509111381,"sku":"4064797:1-VAT145:e14","price":2317.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/1611\/files\/66e81064a437ffa84861e416f9fa2860_025fdd72-6469-4760-bbd4-bc014dcac408.jpg?v=1706932789","url":"https:\/\/www.tanotis.com\/products\/lem-hob-100-p-current-sensor-voltage-output-1-25-accuracy-250-to-250-a-4-6-to-5-5-v","provider":"Tanotis","version":"1.0","type":"link"}