{"product_id":"areca-arc-4036-8-bay-6-gbps-sas-tower-jbod-enclosure","title":"Areca ARC-4036 8-Bay 6 Gbps SAS Tower JBOD Enclosure","description":"\u003cul\u003e \u003cli\u003eSupports up to 8x 6 Gbps SAS\/SATA Drives\u003c\/li\u003e \u003cli\u003e2x SAS Host In Connectors\u003c\/li\u003e \u003cli\u003e2x SAS Expansion Out Connectors\u003c\/li\u003e \u003cli\u003e6-Pin UART RJ-11 Connector\u003c\/li\u003e \u003cli\u003e8x SAS Hard Drive Connectors\u003c\/li\u003e \u003cli\u003e2x 2700 rpm\/Brushless Fans\u003c\/li\u003e \u003c\/ul\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cp\u003e The \u003cb\u003eARC-4036 8-Bay 6 Gbps SAS Tower JBOD Enclosure\u003c\/b\u003e from \u003cb\u003eAreca\u003c\/b\u003e provides a compact external storage chassis capable of accommodating up to eight 6 Gbps Serial-Attached SCSI (SAS) or Serial ATA (SATA) drives. The SAS expander module is based on the LSI 28-port LSISAS2x28 expander IC, SAS-2 chip which features 28 x 6 Gbps ports and 6G\/3G multiplexing, SAS 2.0 zoning, self-configuration, table-to-table routing and an integrated PPC processor for SES-2 and enclosure management support. \u003c\/p\u003e The compact tower enclosure connects to the host system through two 4-lane SAS connectors (host in) and two 4-lane SAS connectors (exp. out) to the next SAS-to-SAS JBOD enclosure. It is used to enhance the ARC-8040 RAID Subsystem by allowing support for more than 8 internal hard disk drives. Configuration and environmental information are accessible either via in-band (SES-2 over SMP) or out-of-band serial port. \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdl\u003e \u003cdt\u003eSAS for Maximum Scalability\u003c\/dt\u003e \u003cdd\u003eSAS 2.0 is designed for backwards compatibility with SAS 1.0 and delivers a data transfer rate of 6 Gbps per physical link. The SAS 2.0 interface supports both 6 Gbps SAS 2.0 disk drives for data-intensive applications and 6 Gbps SATA drives for low-cost bulk storage of reference data. Applications can be optimized for cost\/performance through the use of both SAS and SATA drive types. The enclosure includes 8 internal and 16 external 6 Gbps SAS ports connection for host and easy expansion. High-performance architecture sets new boundaries of industry performance expectations - 6 Gbps SAS (600 MBps bandwidth per physical link) 3 Gbps SATA (300 MBps bandwidth per physical link).\u003c\/dd\u003e \u003c\/dl\u003e \u003cdl\u003e \u003cdt\u003eEasy Management\u003c\/dt\u003e \u003cdd\u003eThe expander box contains an embedded expander manager that can access via in-band SES-2 over SMP protocol and out-of band RS-232 port. An out-of-band serial port is available for managing the configuration and monitoring the expander. The expander firmware and EPLD have implemented the SES-2 protocol and disk activity map to the individual fault\/activity status indicator on the backplanes. Furthermore, it has implemented autonomous chassis management of power supply status connectors and two fan monitor\/speed control connectors through the SES-2 protocol. In data center environments, identifying issues with drives and environments are crucial. The hardware monitor can check system voltage and temperature. The warning message will be shown in alarm buzzer and the respective LED.\u003c\/dd\u003e \u003c\/dl\u003e \u003cdl\u003e \u003cdt\u003eMaximum Interoperability\u003c\/dt\u003e \u003cdd\u003eAreca presents its high performance and high reliability 6 Gbps SAS expander module for a cost-effective and enterprise-class JBOD storage enclosure. A 6 Gbps SAS expander module literally expands the number of end devices that you can connect together. Expander devices, typically embedded into an expander module to connect system backplane, support large configurations of SAS end devices, including SAS host\/RAID adapters and SAS and SATA disk drives. The SAS protocol defines a mechanism that has been implemented in the SAS expanders to guarantee fair access between drives in a domain. The enclosure is ideal for 6 Gbps SAS storage systems with external interfaces and provides the benefits of increased storage capacity. The type and total amount of drives you use are based on the host interface in the server that the JBOD is connected to. Host-based RAID configuration is supported via an external SAS\/Fibre\/iSCSI\/PCIe 2.0 to 6 Gbps SAS RAID controllers, external series 6 Gbps SAS RAID and SAS host adapters.\u003c\/dd\u003e \u003c\/dl\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e\u003cdiv\u003e \u003cdiv\u003eIn the Box\u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003eAreca ARC-4036 8-Bay 6 Gbps SAS Tower JBOD Enclosure\u003c\/div\u003e \u003c\/div\u003e \u003cul\u003e \u003cli\u003e3-Year Warranty\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003cdiv\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eDrives\u003c\/td\u003e \u003ctd\u003e Up to 8 x 2.5\" or 3.5\" SAS hot-plug hard drives (6.0 Gbps) at speeds of 7.2K, 10K or 15K rpm \u003cbr\u003e Up to 8 x 2.5\" or 3.5\" SATA hot-plug hard drives (6.0 Gbps) at speeds of 7.2K or 10K rpm \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eJBOD Controller Modules\u003c\/td\u003e \u003ctd\u003e Expander Board: 1 x module \u003cbr\u003e Sensors: 1 x sensor on the expander board \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eConnectors\u003c\/td\u003e \u003ctd\u003e Backplane Board: \u003cbr\u003e 8 x SAS hard-drive connectors \u003cbr\u003e 1 x power supply connector \u003cbr\u003e 2 x cooling fan module connectors \u003cbr\u003e 1 x set of expander board connector \u003cbr\u003e \u003cbr\u003e Controller Back-Panel: \u003cbr\u003e SAS Connectors (Per Expander Board): \u003cbr\u003e 2 x SAS \"host in\" connectors for connection to the host \u003cbr\u003e 2 x SAS \"expansion out\" connectors for expansion to an additional JBOD enclosure \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLED Indicators\u003c\/td\u003e \u003ctd\u003e Hard-Drive Carrier: 1 x blue single-color activity LED \u003cbr\u003e 1 x two-color LED status indicator per drive \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eExpander\u003c\/td\u003e \u003ctd\u003e 2 x one-color LED status indicators for each SAS host port, 1 x for SAS host port link and 1 x for the activity status \u003cbr\u003e 2 x one-color LED status indicators for each SAS expansion port, 1 x for SAS expansion port link and 1 x for the activity state \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSerial Connector\u003c\/td\u003e \u003ctd\u003e1 x 6-pin UART RJ-11 connector\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCooling Fan\u003c\/td\u003e \u003ctd\u003e 2 x 2700 rpm\/brushless fans \u003cbr\u003e 0.135 A \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003e \u003ca\u003ePower\u003c\/a\u003e \u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e 220 W maximum continuous \u003cbr\u003e 90 - 256 V rated \u003cbr\u003e 50 - 60 Hz \u003cbr\u003e +12 V\/16 A, +5 V\/16 A, +3.3 V\/14 A \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003e \u003ca\u003eEnvironmental\u003c\/a\u003e \u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTemperature\u003c\/td\u003e \u003ctd\u003e Operating: 32 to 104ï¿½F (0 to 40ï¿½C) \u003cbr\u003e Storage: -40 to 140ï¿½F (-40 to 60ï¿½C) \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRelative Humidity\u003c\/td\u003e \u003ctd\u003e Operating: 10 to 80% (non-condensing) \u003cbr\u003e Storage: 5 to 95% (non-condensing) \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003e \u003ca\u003ePhysical\u003c\/a\u003e \u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions (WxHxD)\u003c\/td\u003e \u003ctd\u003e5.75 x 11.89 x 11.42\" (146 x 302 x 290 mm)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e14.9 lb (6.8 kg) without disk\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003e \u003ca\u003ePackaging Info\u003c\/a\u003e \u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePackage Weight\u003c\/td\u003e \u003ctd\u003e17.45 lb\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBox Dimensions (LxWxH)\u003c\/td\u003e \u003ctd\u003e15.2 x 13.8 x 7.9\"\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e All product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.","brand":"Areca-22","offers":[{"title":"Default Title","offer_id":35110258576,"sku":"ARARC4036:ARARC4036:bhpv","price":176400.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/1611\/products\/areca_arc_4036_8_bay_sas_enclosure_1380646092000_1001223.jpg?v=1575982705","url":"https:\/\/www.tanotis.com\/products\/areca-arc-4036-8-bay-6-gbps-sas-tower-jbod-enclosure","provider":"Tanotis","version":"1.0","type":"link"}