{"product_id":"amx-nx-1200-netlinx-nx-integrated-controller","title":"AMX NX-1200 NetLinx NX Integrated Controller","description":"\u003cdiv\u003e\n \u003ch2\u003eAMX FG2106-01 Overview\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003cp\u003eAdd a programmable network appliance to your government, education, or enterprise network for control over all your devices with the \u003cb\u003eNX-1200 NetLinx NX Integrated Controller\u003c\/b\u003e from \u003cb\u003eAMX\u003c\/b\u003e. This compact unit provides a secure connection to a network to control and monitor an A\/V system, HVAC, power, security, and other physical devices via various communication formats, connection types, and remote applications.\u003c\/p\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       IPv6\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       The NX-1200 supports IPv6, the communications protocol that provides an identification and location system for computers on networks and routes traffic across the internet.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       IEEE 802.1X\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       The IEEE 802.1X standard for port-based network access control is supported, with the ability to grant or deny network access to devices wishing to attach to a LAN based on credentials tied to the device rather than to a user.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       X.509 Certificate Services\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Customer-provided certificates are supported for access to protected networks.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Full LDAP Integration\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       There is support for multiple user-defined login groups for accessing the master, and it provides an AMX programmer the capability to require network login to access certain areas of the touch panel.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       High-Performance Architecture\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       The unit provides scalability to support a wide range of applications with a Flexible Programming Platform (RPM, NetLinx, and Java).\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Backwards and Cross-Compatibility\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Standardized port numbers and new configuration import\/export tools mean fewer coding changes across the line.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       TLS\/SSH Client\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       A TLS\/SSH client provides NetLinx programmers the ability to manage secure port TLS and SSH communications with a remote device or server\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Cryptographic Support\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       The device can be deployed in accordance with FIPS 140-2, a U.S. government computer security standard used to accredit cryptographic modules for the protection of sensitive or valuable data.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Network Syslog\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       The unit supports standard device logging to a syslog server.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Enhanced Diagnostics\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Real-time error feedback is provided when serial and IR ports are disconnected or improperly wired.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       File Import\/Export from USB Drive\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Backup and restore configuration data, program files, and update firmware from a standard USB flash drive.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Operation\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       The hardware and software design provide 24\/7\/, 365-day reliability and improved diagnostics.\n      \u003c\/div\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv\u003e\n     UPC: 718878024287\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003ch4\u003eItems Included\u003c\/h4\u003e\n   \u003cul\u003e\n    \u003cli\u003e\u003cspan\u003eAMX NX-1200 NetLinx NX Integrated Controller\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003e2-Pin 3.5mm Mini-Terminal (Female) PWR Connector\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003e4-Pin 3.5mm Mini-Terminal (Female) AxLink Connector\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003e6-Pin 3.5mm Mini-Terminal (Female) I\/O Connector\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003e10-Pin 3.5mm Mini-Terminal (Female) RS-232\/422\/485 Connector\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003e5-Pin 3.5mm Mini-Terminal (Female) RS-232 Connector\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003e\u003cspan\u003eAMX IR LED Cable with 3.5mm Phoenix\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n    \u003cli\u003e\u003cspan\u003eLimited 1-Year Manufacturer Warranty\u003c\/span\u003e\u003c\/li\u003e\n   \u003c\/ul\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n \u003ch4\u003eAdditional Resources \u003c\/h4\u003e\n \u003cdiv\u003e\n  \u003ca\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\u003c\/div\u003e\n    \u003cdiv\u003e\n     \u003cp\u003eQuickstart Guide\u003c\/p\u003e\n     \u003cp\u003e0.2 MB\u003c\/p\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\u003c\/a\u003e\n \u003c\/div\u003e\n \u003cul\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n \u003cdiv\u003e\n  \u003cdiv\u003e\n   \u003cdiv\u003e\n    \u003cdiv\u003e\n     \u003cdiv\u003e\n      \u003ch2\u003eAMX FG2106-01 Specs\u003c\/h2\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       General\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eRAM\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eNVRAM: 4 GB \u003cbr\u003e DDRAM: 512 MB\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Inputs\/Outputs\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eUSB I\/O\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e1 x USB-B Female Input\u003cbr\u003e1 x USB-A Female Input\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eOther I\/O\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e20-Pin Terminal Block (RS-232\/422\/485)\u003cbr\u003e 1 x 5-Pin Terminal Block (RS-232)\u003cbr\u003e 1 x 4-Pin Terminal Block (AxLink)\u003cbr\u003e 1 x 2-Pin Power, 12 VDC\u003cbr\u003e 1 x RJ45 10\/100 Ethernet LAN\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Power\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003ePower Source\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eAC Input\u003cb\u003e\u003c\/b\u003e\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eDC Input Power\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e12 VDC\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003ePower Consumption\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e3 W\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eOperating Current\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e200 mA\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n     \u003cdiv\u003e\n      \u003cdiv\u003e\n       Physical\n      \u003c\/div\u003e\n      \u003ctable\u003e\n       \u003ctbody\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eColor\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003eBlack\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eOperating Conditions\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e32 to 122?F \/ 0 to 50?C at 5 to 85% Humidity \u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eStorage Conditions\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e14 to 140?F \/ -10 to 60?C at 5 to 85% Humidity \u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eDimensions\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e5.8 x 5.15 x 1.66\" \/ 147.32 x 130.81 x 42.16 mm\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n         \u003ctd\u003eWeight\u003c\/td\u003e\n         \u003ctd\u003e\n          \u003cdiv\u003e\n           \u003cspan\u003e1.6 lb \/ 726 g\u003c\/span\u003e\n          \u003c\/div\u003e\n\u003c\/td\u003e\n        \u003c\/tr\u003e\n       \u003c\/tbody\u003e\n      \u003c\/table\u003e\n     \u003c\/div\u003e\n    \u003c\/div\u003e\n   \u003c\/div\u003e\n  \u003c\/div\u003e\n \u003c\/div\u003e\n\u003c\/div\u003e\u003cbr\u003eAll product and company names are trademarks™ or registered® trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.","brand":"AMX-22","offers":[{"title":"Default Title","offer_id":41974131294293,"sku":"AMNX1200:AMNX1200:bhpv","price":248350.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/www.tanotis.com\/products\/amx-nx-1200-netlinx-nx-integrated-controller","provider":"Tanotis","version":"1.0","type":"link"}